Implementasi Sistem Monitoring Deteksi Volume Infus Secara Real-Time Menggunakan Interface Android

Hari, Fauzan Iqbal (2022) Implementasi Sistem Monitoring Deteksi Volume Infus Secara Real-Time Menggunakan Interface Android. Undergraduate Thesis thesis, Institut Teknologi Telkom Purwokerto.

[img] Text
1. COVER.pdf

Download (323kB)
[img] Text
2. abstract .pdf

Download (49kB)
[img] Text
3. abstrak.pdf

Download (30kB)
[img] Text
4. BAB I.pdf

Download (138kB)
[img] Text
5. BAB II.pdf

Download (364kB)
[img] Text
6. BAB III.pdf

Download (550kB)
[img] Text
7. BAB IV.pdf
Restricted to Registered users only

Download (1MB) | Request a copy
[img] Text
8. BAB V.pdf

Download (33kB)
[img] Text
9. DAFTAR PUSTAKA.pdf

Download (95kB)
[img] Text
10. LAMPIRAN.pdf
Restricted to Registered users only

Download (251kB) | Request a copy

Abstract

Infusion is a medical device that under certain conditions is used to replace lost fluids and balance the body's electrolytes. One of the nurse's duties is to unite the infusion. The process of monitoring the infusion must be done properly. Currently, infusion monitoring is still done manually, which means checking the condition of the patient's infusion directly. When the infusion runs out, the nurse has limited time to go to the patient's room, which can cause the patient to be treated late. This research was carried out with the concept of the Internet of things aimed at simplifying the process of monitoring the volume of infusion. The author utilizes the infusion volume monitor by designing a tool using the HX711 Load Cell sensor which will later be combined into a single unit. then connected to the internet network using the NodeMCU module so that the infusion can be monitored via the Blynk platform that has been connected to Firebase. The average result of the comparison between the infusion Error 1 is 0.04% and the infusion Error 2 is 0.20%. The results of observations of the average Throughput obtained during observations in 1 day every 10 minutes/data is worth 200.00 bits/s. The average result of Packet Loss testing gets a value of 0%. the results of the measurement of the average total Delay of the NodeMCU module sending data to the Blynk platform is 4.4000 ms. Keywords: Infusion, NodeMCU, Load Cell, QoS (Quality of Service), TIPHON

Item Type: Thesis (Undergraduate Thesis)
Subjects: T Technology > T Technology (General)
Divisions: Faculty of Telecommunication and Electrical Engineering > Telecommunication Engineering
Depositing User: pustakawan ittp
Date Deposited: 14 Apr 2022 06:01
Last Modified: 14 Apr 2022 06:01
URI: http://repository.ittelkom-pwt.ac.id/id/eprint/7284

Actions (login required)

View Item View Item