Sistem Monitoring Gas Karbon Dioksida Dan Gas Karbon Monoksida Berbasis NODEMCU ESP 8266

Aziz, Muhammad Nadzir (2021) Sistem Monitoring Gas Karbon Dioksida Dan Gas Karbon Monoksida Berbasis NODEMCU ESP 8266. Undergraduate Thesis thesis, Institut Teknologi Telkom Purwokerto.

[img] Text
cover.pdf

Download (263kB)
[img] Text
ABSTRACT.pdf

Download (83kB)
[img] Text
ABSTRAK.pdf

Download (85kB)
[img] Text
bab 1.pdf

Download (166kB)
[img] Text
bab 2.pdf

Download (343kB)
[img] Text
bab 3.pdf

Download (634kB)
[img] Text
bab 4.pdf
Restricted to Registered users only

Download (123kB) | Request a copy
[img] Text
lampiran.pdf
Restricted to Registered users only

Download (284kB) | Request a copy
[img] Text
bab 5.pdf

Download (85kB)
[img] Text
daftar pustaka.pdf

Download (163kB)

Abstract

Air is an important part of human life. Along with the times, air pollution is increasing from year to year. Air pollution refers to the presence of one or more hazardous chemical, physical or biological substances in the atmosphere. Carbon monoxide (CO) gas produced by vehicles has various effects on the human body. Carbon (CO2) is the most important greenhouse gas that causes global warming, and is stored in the atmosphere due to human activities. By using Internet of Things technology it can be done to monitor the quality of carbon dioxide gas and carbon monoxide gas using the MICS 5524 (Carbon Monoxide) sensor and CCS 811 (Carbondioxide) sensor with this NodeMCU used as the main controller in the system to be made and also as a medium in sending data results to Thingspeak. The data transmission uses the ESP8266 wifi module media that has been installed on the NodeMCU with an internet connection. The research was conducted in an open space on Jl. Banyumas district guerrilla. The results of testing the accuracy of the sensor when testing by comparing it with the AS8700A and AR8200 tools. The MICS 5524 sensor has an average error of 2.953% and the CCS 811 sensor has an average error of 0.2633%. The QoS results obtained from the test results the average delay obtained is 0.3452 seconds or 345.2 ms. The average jitter is 0.0535 s or 53.5 ms. get an average Throughput of 165,655 bytes/s. Keywords: Air Quality, Monitoring, Internet of Things, Carbon Dioxide, Carbon monoxide, NodeMCU ESP8266, Thingspeak

Item Type: Thesis (Undergraduate Thesis)
Subjects: T Technology > T Technology (General)
Divisions: Faculty of Telecommunication and Electrical Engineering > Telecommunication Engineering
Depositing User: pustakawan ittp
Date Deposited: 14 Dec 2021 04:02
Last Modified: 14 Dec 2021 04:02
URI: http://repository.ittelkom-pwt.ac.id/id/eprint/6752

Actions (login required)

View Item View Item