Yusuf, Hidayat (2020) Analisis Perfomansi Jaringan Indoor Building Coverage Pada Layanan 4G LTE XL Axiata Di Plaza Baru Ciledug Kota Tangerang Banten. Technical Report. Pustakawan, Perpustakaan Institut Teknologi Telkom Purwokerto. (Unpublished)
|
Text
COVER.pdf Download (582kB) | Preview |
|
|
Text
ABSTRACT.pdf Download (316kB) | Preview |
|
|
Text
ABSTRAK.pdf Download (317kB) | Preview |
|
|
Text
BAB I.pdf Download (458kB) | Preview |
|
|
Text
BAB II.pdf Download (550kB) | Preview |
|
Text
BAB III.pdf Restricted to Registered users only Download (316kB) | Request a copy |
||
|
Text
BAB IV.pdf Download (3MB) | Preview |
|
|
Text
DAFTAR PUSTAKA.pdf Download (414kB) | Preview |
|
Text
LAMPIRAN.pdf Restricted to Registered users only Download (3MB) | Request a copy |
Abstract
Development in the world of telecommunication is growing rapidly and is already a basic need for people who want to communicate comfortably, seamlessly and infinitely. So mobile telecommunication service providers are required to develop to meet the needs of consumers, one of which is the need for data package communication. Mobile communication system with 4G Long Term Evolution (LTE) technology is one of the most widely used technologies in the world. Every communication network service provider strives to provide the best service. In relation to services provided over the LTE network there are some things that may still occur problems. Communication occurs when the signal quality is maintained properly. In indoor building areas, poor eNodeB performance such as lack of radiance and many obstacle factors in the eNodeB coverage area. This allows Mobile Station (MS) to experience a weakening of the received signal so that there may be an MS failure in communication. Therefore, network maintenance is required to keep the signal quality in Indoor Building Coverage (IBC) well maintained. The method used is the measurement of Walk Test at Plaza Baru Ciledug Tangerang Banten site based on Physical Cell Identification (PCI), Reference Signal Received Power (RSRP), Signal Interference to Noise Ratio (SINR), parameters. The results obtained from the test with the Walk Test method, network performance in Plaza Baru Ciledug Tangerang can be said to be optimal because of the overall RSRP data the results of the Walk Test are 99.71% ≥ (-100 dBm). Then on PCI IBC parameter data 100.00% and on SNR parameters 93.51% ≥ (5 dB). Keywords: 4G LTE, Walk Test, Parameters, Indoor Building Coverage
Item Type: | Monograph (Technical Report) |
---|---|
Subjects: | T Technology > T Technology (General) |
Divisions: | Faculty of Telecommunication and Electrical Engineering > Telecommunication Engineering |
Depositing User: | pustakawan ittp |
Date Deposited: | 27 Jul 2021 05:10 |
Last Modified: | 27 Jul 2021 05:10 |
URI: | http://repository.ittelkom-pwt.ac.id/id/eprint/6261 |
Actions (login required)
View Item |