Rudy, Dharmawan (2018) analisis perbandingan quality of service jaringan 2G dan 3G dengan metode drive test di Kabupaten Blora. Technical Report. studentstaff5, Perpustakaan Institut Teknologi Telkom Purwokerto. (Unpublished)
|
Text
COVER.pdf Download (1MB) | Preview |
|
|
Text
ABSTRAK.pdf Download (193kB) | Preview |
|
|
Text
ABSTRACT.pdf Download (198kB) | Preview |
|
|
Text
BAB I.pdf Download (538kB) | Preview |
|
Text
BAB II.pdf Restricted to Registered users only Download (1MB) | Request a copy |
||
Text
BAB III.pdf Restricted to Registered users only Download (1MB) | Request a copy |
||
|
Text
DAFTAR PUSTAKA.pdf Download (142kB) | Preview |
|
|
Text
LAMPIRAN.pdf Download (1MB) | Preview |
Abstract
The advancement of the world of technology raises the need for telecommunication that runs smoothly every year. Considering that telecommunication needs are very important for human life, they must get special attention and increase every year. Quality and range are things that must be mei properly. Drive test is one method that is used to find information about networks directly in the field. In the drive test itseffsometimes gets results that are not in accordance with the target, then a retest drive is done to get good results. fir the first drive test, 36 technology was used and the second test drive was 2G and 3G, when the drive retested it got different results. Therefore a comparison of the results of the first and second drive testy was made to .find out what was different from the first and second drive tests. To_find out how good the network quality is in 2G and 3G technology. After the drive lest and data processing are done, we can get a comparison of the results of the data, both of which have different values. Where Ecno in the first drive test was 86.5% worse than the second drive lest which was 90,8%, but the drop call occurred twice and the block call twice, many of which occurred in the second drive test with 2G and 3G technologr. But there is the first and second CST avg drive test that gets the same value which is 3.6 seconds. Of the five parameters measured namely' Ecno, Rscp, Rxlevel, Rxqual and SQI MOS, in the first and second drive tests the second ecno drive test got the best, 90.8%. Keywords: Test Drive, Actix Analyzer, TEMS Investigation, Ecno, Maphifo
Item Type: | Monograph (Technical Report) |
---|---|
Subjects: | T Technology > T Technology (General) |
Divisions: | Faculty of Telecommunication and Electrical Engineering > Diploma of Telecommunication Technology |
Depositing User: | KinatJr |
Date Deposited: | 01 Mar 2019 04:57 |
Last Modified: | 01 Mar 2019 04:57 |
URI: | http://repository.ittelkom-pwt.ac.id/id/eprint/5241 |
Actions (login required)
View Item |